VasoMedical Lumenair™ All-In-One EECP® Therapy System
The Lumenair EECP® Therapy System combines proven medical technology with enhanced styling in a compact model that’s easy to operate. As a result, therapists use it with confidence and physicians rely on its performance at hundreds of centers worldwide.
Key features:
Trinity Pneumatic Delivery System
Integrated Work Surface
Comfortcurve™ Treatment Mattress
Welded Steel Frame Construction
Single Plethysmographic/SpO2 Probe
Autochart Software
ECM Module (Optional)
DELIVERING A NEW AIR OF CONFIDENCE
The all-in-one LumenairTM EECP⑧Therapy System is the state-of-the -art enhanced external counterpulsation system from Vasomedical, the world leader in external
counterpulsation technology.
Backed by years of clinical research and numerous published data, the Lumenair TmM system incorporatesthe proven performance of EECP⑧technology in a sleek, selfcontained unit that is easy to use and fosters patient confidence, comfort and compliance.
ADVANCED TECHNOLOGY
■Unique, proprietary timing algorithm based upon years of clinical data and expertise.
■Patented pneumatic system delivers optimal therapeutic pressure consistently, safely and comfortably.
■Close-loop pressure stabilization system monitors air pressure beat by beat and ensures consistent effective treatment pressure over a wide range of heart rates.
■AutoChart software automatically captures patient treatment data during EECP⑧therapy. A summary of timed snapshots, which include ECG and plethesmograph waveforms taken
at varying intervals, can be printed or stored electronically.
CONVENIENCE AND EASE OF USE
■Color touch screen display provides a simple, convenient and efficient way to monitor the patient while controlling system operation. All information and treatment controls displayed on
one screen.
■Integrated work station and display, which can be mounted on either side of the table.
■ComfortCurveTM treatment table top with quality foam mattress and pillow provide better patient positioning for comfort and compliance. 1 I Small footprint allows system to fit in most
treatment rooms.
■TwilockTM, a proprietary cuff quick connect/ disconnect system enables easy change of cuffs between patients.
VASOMEDICAL® - LUMENAIR™ EECP® THERAPY SYSTEM SPECIFICATIONS
ECG Amplifier
Input impedance:>2 MQ
Common mode
rejection ratio:>90 dB
Bandwidth:1-20 Hz on displa
SpO2 Oxygen Saturation
Oxygen saturation range: 0 to 100%
Accuracy Sp02 (土1 Standard Deviation) 70- 100%土2 digits for adults using the Finger Clip Sensor
70- 100%土3 digits for adults using Flex or Reflec- tance Sensors
70-100%土4 digits using Ear Clip Sensor Below 70% is not specified for all sensors
Triggering Method
External trigger:R-wave of patient ECG
External trigger ratio:1:1 or 1:2
ECG trigger range:35- 125 +1 bpm
Filter Technique
Low-pass digital flter eliminates 50/60 Hz and high frequency interference.
Treatment Pressure Range
Adjustable from 80300 mmHg
Cuffs
Each set includes calf, lower thigh and upper tighbutok cuffs.
Table Safe Working Load
400 Ib (180 kg)
Treatment Session Timer
Set treatment time up to 60 minutes maximum. System
automatically stops when set time expires
System Protection
Three circuit breakers一Mains and compressor, and a
built-in circuit breaker in the power switch on the front
panelTreatment Session Timer
Set treatment time up to 60 minutes maximum. System
atomatically stops when set time expires
Patient Protection / Safety
1. Automatic inflation stop and pressure release on early extra systole.
2. Automatic treatment stop and pressure release if power outage occurs.
3. Automatic high-pressure limit.
4. Automatic treatment stop if heart rate goes out of range (35-125 bpm).
5. Emergency stop hand-held button (actuated by patient).
6. Alarm with auditory signal on stop events (except a power outage).
Equipment Dimensions and Weight
Height: 42″ (107 cm)
Width: 34″ (87 cm)
Length: 78.5″ (200 cm)
Weight: 550 lb (250 kg)
Operating Voltage Requirements (switch selectable)
115VAC, 50/60 Hz, 20A 230VAC, 50/60 Hz, 15A
Operating Environment
Temperature: 50 to 104° F (10 to 40° C)
Relative Humidity: 30 to 75% (no condensation)
Atmospheric Pressure: 700 to 1060 hPa
Atmosphere: Free of corrosive gas
Transport and Storage Environment
Temperature: 14 to 140° F (-10 to 60° C)
Relative Humidity: 30 to 85% (no condensation)
Atmospheric Pressure: 500 to 1060 hPa
Atmosphere: Free of corrosive gas
EECP is a registered trademark of Vasomedical, Inc. Lumenair, ComfortCurve and AutoChart are trademarks of Vasomedical, Inc.
Recommend
-
-
QQ Zone
-
Sina Weibo
-
Renren.com
-
Douban