|
VasoMedical Lumenair™ All-In-One EECP® Therapy SystemThe Lumenair EECP® Therapy System combines proven medical technology with enhanced styling in a compact model that’s easy to operate. As a result, therapists use it with confidence and physicians rely on its performance at hundreds of centers worldwide. Key features:
DELIVERING A NEW AIR OF CONFIDENCE The all-in-one LumenairTM EECP⑧Therapy System is the state-of-the -art enhanced external counterpulsation system from Vasomedical, the world leader in external Backed by years of clinical research and numerous published data, the Lumenair TmM system incorporatesthe proven performance of EECP⑧technology in a sleek, selfcontained unit that is easy to use and fosters patient confidence, comfort and compliance. ADVANCED TECHNOLOGY ■Unique, proprietary timing algorithm based upon years of clinical data and expertise. CONVENIENCE AND EASE OF USE ■Color touch screen display provides a simple, convenient and efficient way to monitor the patient while controlling system operation. All information and treatment controls displayed on VASOMEDICAL® - LUMENAIR™ EECP® THERAPY SYSTEM SPECIFICATIONS ECG Amplifier SpO2 Oxygen Saturation Oxygen saturation range: 0 to 100% Triggering Method Filter Technique Low-pass digital flter eliminates 50/60 Hz and high frequency interference. Treatment Pressure Range Cuffs Table Safe Working Load Treatment Session Timer System Protection Patient Protection / Safety 1. Automatic inflation stop and pressure release on early extra systole. 2. Automatic treatment stop and pressure release if power outage occurs. 3. Automatic high-pressure limit. 4. Automatic treatment stop if heart rate goes out of range (35-125 bpm). 5. Emergency stop hand-held button (actuated by patient). 6. Alarm with auditory signal on stop events (except a power outage). Equipment Dimensions and Weight Height: 42″ (107 cm) Width: 34″ (87 cm) Length: 78.5″ (200 cm) Weight: 550 lb (250 kg) Operating Voltage Requirements (switch selectable) 115VAC, 50/60 Hz, 20A 230VAC, 50/60 Hz, 15A Operating Environment Temperature: 50 to 104° F (10 to 40° C) Relative Humidity: 30 to 75% (no condensation) Atmospheric Pressure: 700 to 1060 hPa Atmosphere: Free of corrosive gas Transport and Storage Environment Temperature: 14 to 140° F (-10 to 60° C) Relative Humidity: 30 to 85% (no condensation) Atmospheric Pressure: 500 to 1060 hPa Atmosphere: Free of corrosive gas EECP is a registered trademark of Vasomedical, Inc. Lumenair, ComfortCurve and AutoChart are trademarks of Vasomedical, Inc. |